Dlro200-115 manual
Megger DLROV Amp Digital Low Resistance Ohmmeter with blocking filter. Compact lightweight unit weighs less than 7 lbs it is at home in workshop, on production floor, or testing in fiel. Onboard memory for up to test results notes. Three modes of operation - Manual, Continuous or Automatic. The power lead entry is located on the left-hand side panel and marked “ V a.c., 10 A max., 50/60Hz” for the DLRO, or ‘ V a.c. Before a test may be started the potential test lead contact is monitored 10 A max. 50/60Hz’ for the DLRO The main On/Off switch is to ensure good contact is present. · “ V a.c., 10 A max., 50/60Hz” for the DLRO, or ‘ V a.c. 10 A max. 50/60Hz’ for the DLRO The main On/Off switch is located next to the power lead entry. All other controls are mounted on the front panel. Should the supply earth be inadequate the instrument will refuse to switch on, the display will remain www.doorway.ru Size: KB.
Power Supply DLRO for full output (unsmoothed d.c.): to V 50/60 HZ with a load less than 19 mΩ(supply V rms), or 11 mΩ( V rms) including current leads Power Supply DLRO for full output (additional smoothing): to V 50/60 HZ with a load less than 11 mΩincluding current leads Test Modes: Manual, Auto, Continuous. Power Supply for DLRO for full output (unsmoothed d.c.) to V 50/60 Hz with a load less than 19 mΩ (supply V rms), or 11 mΩ ( V rms) including current leads: Power Supply for DLRO V for full output (additional smoothing) to V 50/60 Hz with a load less than 11 mΩ including current leads: Test Modes: Manual. Power Supply for DLRO for Full Output (unsmoothed d.c.) to V 50/60 Hz with a load less than 19 mΩ (supply V rms) or 11 mΩ ( V rms) including current leads: Power Supply for DLRO V for Full Output (additional smoothing) to V 50/60 Hz with a load less than 11 mΩ including current leads: Test Modes: Manual.
Add To Quote Request Digital Manual Product Details The Megger DLRO A Digital Low Resistance Ohmmeter measures contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any other low resistance measurement. The Megger DLRO Digital Low Resistance Ohmmeter is designed to check and measure contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any low resistance measurement. The test set accurately measure resistances ranging from μΩ to 1Ω, at high currents. Megger Ducter™ DLRO measures resistances between µΩ and 1 Ω, at high currents. This versatile instrument can provide test currents from 10 amps up to amps subject to the load resistance and supply voltage. A large LCD displays all all test parameters and measurement results. For over years the ‘Ducter test’ has been used.
0コメント